DVF™ 900 Industrial

high - efficiency water filtration systems

  • DESCRIPTION
  • SPECIFICATION
  • Filtration performance
  • 0.45, 1, 5, 10 µm Nominal
  • Number of vessels
  • 1 Unit
  • Vessel diameter
  • 900 mm nominal
  • Filtration flow rate
  • 13 - 40m3/hr
  • Backwash loss
  • 0.53 m3
  • Backwash flow rate at 2barg
  • 13 m3/hr
  • Backwash duration
  • 2 - 4 Minutes (Adjustable)
  • Vessel construction
  • ST/S 304L
  • Valves
  • Electric Actuated 24VAC
  • Media type
  • Graded Glass
  • Piping & fittings
  • Standard: PVC 2" Class E
    Optional: ST/S or other
  • Process pump specification
  • Cast iron body - Centrifugal type
  • Control panel
  • IP55 380mm X 300mm X 120mm
  • Control panel supply voltage
  • 240V, Single phase, 50Hz  0.5 Amps Supply Voltage
    24 VAC Control Voltage
  • Auxiliary DOL starter panel
  • 440V, Three phase, 50Hz  9.1amp supply voltage
    240 VAC Control Voltage
  • Process inlet connection
  • DN 50 ISO Flanged
  • Process water outlet connection
  • DN 50 ISO Flanged
  • Backwash inlet connection
  • DN 50 ISO Flanged
  • Backwash outlet (to drain) connection
  • DN 50 ISO Flanged
  • Minimum operating pressure
  • 1 barg
  • Maximum operating pressure
  • 7 barg
  • Maximum operating temperature
  • 65 °C
  • Installation space required
  • L 1600 mm X W 1500 mm X H 2500 mm (3200mm for maintenance)
  • Approximate shipping weight
  • 1800 Kg

Construction Materials

FILTER HOUSING AND LID*
SS 304 Built according to PED 5500:2006 Category 3.

NOZZLES*
Polypropylene for use below 60 degrees.

GASKETS*
Synthetic rubber, NBR

FILTER MEDIA
4 varying layers of Activated Glass

FILTER BASE*
Galvanised steel

PIPEWORK*
Standard PVCu, copper or stainless steel

Contact

Tel. +44 (0) 1792 277 290
E-mail: info-uk@amiad.com

Visit

Unit 1
Heol Rhosyn
Dafen
LLaneli
SA14 8QG